Ashcroft gauge pressure sensors provide precision pressure measurements in compressed air systems, water, or other compatible gases and fluids. |
| | |
Features and Specifications | |
| |
• | Measurement ranges: 100, 200, 500 psig |
| |
• | Compensated temp range: -40° to 125°C |
| |
• | Accuracy: ±1% FS from -20° to 85°C ±1.5% FS -40° to -20°C and 85° to 125°C |
| |
• | Non-linearity: less than ±0.1% of span typical |
| |
• | Non-repeatability: less than ±0.03% of span typical |
| |
• | Hysteresis: less than ±0.01 of span typical |
| |
• | Stability: less than ±0.25% of span/year |
| | |
• | Durability: tested to 50 million cycles | |
| | |
• | Overpressure: 200% FS | |
| | |
• | Response time: less than 1 msec |
| | |
• | Power: 9-36 VDC, 5mA |
| | |
• | Operating temp range: -40° to 125°C |
| | |
• | Operating humidity range: 0 to 100% RH, no effect |
| | |
• | Output signal to FlexSmart module: 0-5 VDC, 3 wire |
| | |
• | Reverse polarity protected |
| | |
• | Insulation breakdown voltage: 100 VAC |
| | |
• | Insulation resistance: greater than 100 megohms at 100 VDC |
| | |
• | Shielded cable, 24 AWG, PVC jacket, 1-meter |
| | |
• | Pressure connection: 1/4” NPT 304 stainless steel |
| | |
• | Sensor material: 17-4PH stainless steel |
| | |
• | Housing material: 20% glass reinforced nylon, fire retardant to UL94 V1 |
| | |
• | CE Compliance: Per EN 61326: 1997 + A1: 1998 + A2: 2001, Annex A (Heavy Industrial) |
| | |
• | Dimensions: 2.9 cm diameter x 6.4 cm long (1.15 diameter x 2.5 long) |
| | |
• | Weight: 89.4g | |
| | |
• | Requires FlexSmart Analog Module (S-FS-CVIA) |
| | |
• | # data channels: 1 | |
| | |
| | |